Conspire.to
research
Translate this page

Research

Methods for SARS-CoV-2 hospital disinfection, in vitro observations

doi.org · added Oct 2026

Summary

NaDCC at 100, 500 and 1000 ppm, ethanol and chlorhexidine each inactivated three SARS-CoV-2 variants by more than 3 log. 222 nm UV-C did not show time-dependent inactivation and ozonated water gave under 1 log.

Key points

  • 70% ethanol, NaDCC (100 to 1000 ppm) and chlorhexidine (down to 0.5%) each reduced three SARS-CoV-2 variants (alpha, beta, gamma) by more than 3 log.
  • Ozonated water (7 ppm) reduced the virus by less than 1 log.
  • UV-C light at 254 nm reduced viral activity by 1 to 5 log, more after 3 minutes than after 6 seconds.
  • UV-C at 222 nm did not show the time-dependent reduction seen at 254 nm.
  • Design: lab tests on live, cultured virus.
  • Funding: NHS Grampian Charity; je2Care supplied the 222 nm lamp and Novus gave equipment access; no competing interests.